The following points should be observed during slurry pump maintenance:
(1) The bearing’s water pressure and flow rate must comply with the specified requirements; adjust (or replace) the packing gland tightness as needed to prevent slurry leakage from the shaft seal, and replace the shaft sleeve promptly.
(2) When replacing bearings, ensure that the bearing assembly is free of dust and that the lubricant is clean. During pump operation, the bearing temperature should generally not exceed 60–65°C, with a maximum allowable limit of 75°C.
(3) Ensure the coaxial alignment of the motor and the pump, and verify that the elastic coupling pads are intact and correctly installed; replace them promptly if damaged.
(4) Ensure that the pump assembly and piping system are installed correctly and securely.
(5) Certain components of slurry pumps are wear parts; during routine operation, it is essential to monitor their wear and promptly repair or replace them as needed. During the maintenance or replacement of these wear parts, ensure proper assembly and appropriate clearance adjustments to prevent excessive tightness, binding, and friction.
(6) The suction piping system of the slurry pump must be completely airtight, and during operation, care should be taken to ensure that the suction inlet is not blocked. Since the media handled by slurry pumps often contain solid particles, the strainer installed in the pump sump must be capable of passing particles of the size specified for the pump, thereby minimizing the risk of oversized particles or long-fiber materials entering the pump and causing blockages.