Slurry pumps convey a mixture of solid particles and water containing suspended solids.
In principle, slurry pumps are a type of centrifugal pump and are primarily used in steel plants to convey slurries in systems such as converter dust‑removal water, blast‑furnace gas‑washing water, continuous‑casting turbid circulating water, and rolling‑mill turbid circulating water.
The typical structure of a slurry pump is as follows.
(1) Pump head structure. The pump body features a double‑walled casing (an inner and outer metal structure), with a vertically split design. The discharge outlet can be installed at eight distinct positions, rotated in 45° increments. To effectively prevent shaft seal leakage, a combination of mechanical seals, packing seals, or dynamic seals is employed. A labyrinth‑type clearance seal is provided between the impeller and the back liner, significantly reducing slurry leakage into the packing chamber and ensuring reliable sealing performance. The impeller is equipped with back vanes that promptly discharge recirculating slurry, thereby increasing volumetric efficiency, minimizing backflow and erosion, and extending the service life of flow‑path components. For ease of maintenance and disassembly, a removal ring is incorporated, preventing shaft cutting caused by inability to dismantle the unit.
(2) Bracket Structure. The bracket structure is a horizontally split type, and has been optimized in both hydraulic and structural design to extend bearing life. This ensures an appropriate distribution of radial and axial forces, while also enabling the proper selection of bearing type, model, and cooling and lubrication methods, thereby meeting the requirements for low heat generation and long service life.
(3) Shaft sealing configuration. The shaft seal assembly provides a seal between the pump casing and the pump shaft, preventing air from entering the pump and minimizing leakage of liquid from within. Centrifugal slurry pumps typically employ a combination of an auxiliary impeller and packing for sealing. This combined sealing system is a fluid‑dynamic type: the pressure generated by the auxiliary impeller counteracts the outward flow of liquid at the impeller discharge, while back vanes on the impeller cover plate, together with a water seal ring and packing, prevent air ingress. Additionally, the back vanes and water seal ring reduce the pressure at the packing gland, thereby helping to keep contaminants from entering the sealing interface.
Previous
Previous:
Request a Quote
We will contact you within one working day. Please pay attention to your email.
Related Posts
The main significance of dredge pump manufacturers is: